Optional

Telescope.SlewToTarget() Method

Move the telescope to the TargetRightAscension and TargetDeclination coordinates, return when slew complete.

Syntax

Telescope.SlewToTarget()

The method syntax has these parts:

Part Description
Return (Nothing) Does not return a value.

Remarks

This Method must be implemented if CanSlew returns True. Raises an error if the slew fails.

The slew may fail if the target coordinates are beyond limits imposed within the driver component. Such limits include mechanical constraints imposed by the mount or attached instruments, building or dome enclosure restrictions, etc.

Raises an error if AtPark is True, or if Tracking is False.