GuiderAggressivenessX

Property

CCDCamera.GuiderAggressivenessX (Double)

Syntax

CCDCamera.GuiderAggressivenessX [= Double]

Remarks

Sets the guider aggressiveness for the X axis; the valid range is 0.0-10.0.  This setting controls how much of the detected guide star position error on the telescope "X" axis that MaxIm DL will attempt to guide out.  A setting of 10 tells MaxIm DL to correct for ALL of the detected guide error, but this can lead to guiding instability. A setting of 8 or 9 is recommended.  Setting GuiderAggressivenessX to 0 allows you to observe the guide errors, but prevents MaxIm DL from actuating the mount to compensate.

If the current guider is the SBIG w/AO-7, then changing the GuiderAggressiveness property changes the AO-7's aggressiveness, instead of altering the aggressiveness setting on the Guide tab.