Property
CCDCamera.GuiderAggressivenessX (Double)
Syntax
CCDCamera.GuiderAggressivenessX [= Double]
Remarks
Sets the guider aggressiveness for the X axis; the valid range is 0.0-10.0. This setting controls how much of the detected guide star position error on the telescope "X" axis that MaxIm DL will attempt to guide out. A setting of 10 tells MaxIm DL to correct for ALL of the detected guide error, but this can lead to guiding instability. A setting of 8 or 9 is recommended. Setting GuiderAggressivenessX to 0 allows you to observe the guide errors, but prevents MaxIm DL from actuating the mount to compensate.
If the current guider is the SBIG w/AO-7, then changing the GuiderAggressiveness property changes the AO-7's aggressiveness, instead of altering the aggressiveness setting on the Guide tab.